Sign In | Join Free | My enlightcorp.com
China Chongqing Bio Newvision Medical Equipment Ltd. logo
Chongqing Bio Newvision Medical Equipment Ltd.
Build Ophthalmic Equipment Flag Exploit Dignosis New Era
Verified Supplier

5 Years

Home > Digital Fundus Camera >

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto

Chongqing Bio Newvision Medical Equipment Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto

Brand Name : SYSEYE

Model Number : RetiCam 3100

Certification : FDA

Place of Origin : China

MOQ : 1

Price : $12,000.00-$13,000.00

Payment Terms : T/T

Supply Ability : 100

Delivery Time : 5 working days

Packaging Details : 380mm(L)×550mm(W)x475mm(H)

Product name : Digital Fundus Camera

auquisition mode : non-mydriatic/mydriatic

fixation : external fixation/internal fixation

Field View : 50°

Working Distance : 35mm

Minimum Pupil : ≥3.3mm

autofocus assist light : infrared LED

Exposure modes : Auto/manual

Contact Now

ophthalmic fundus camera excellent optic ultra-high resolution fully auto​

ophthalmic fundus camera Reticam 3100 is a highly recognized and popular automatic fundus imaging system around the world. Through dual camera imaging, image control and feature recognition, eye XYZ 3D automatic positioning is realized. Through CCD imaging feedback, the exposure is measured, and the exposure intensity is automatically and accurately determined, without the need for a doctor's complex operation. By controlling the focusing step length according to the image resolution, the image definition can be automatically adjusted to obtain a clear and accurate fundus image and help doctors make accurate judgments for patients.

ophthalmic fundus camera is very important for patients with diabetes and hypertension. In order to prevent fundus lesions, these patients should have regular fundus screening according to the course of disease. With the development of technology, non-dilated technology has improved the accessibility of fundus disease screening due to its advantages of simple operation and high efficiency. Meanwhile, it is also suitable for patients with glaucoma and hypertension who are not suitable for dilated pupil examination. Previously due to the role of dilatation agents, it is possible that hypertension patients after the use of higher blood pressure. Digital Fundus Camera RetiCam 3100 only takes 1.9 minutes for non-dilatation photographic examination, which is very suitable for emergency patients. This technology will have a profound impact on the clinical treatment mode and examination mode.

Acquisition Modes Digital Fundus Camera/mydriatic Anterior photography /Red-free(optional)(FFA)/(FAF)
Field View 50°
Working Distance 35mm
Minimum Pupil ≥3.3mm
Focus Modes Manual/Auto
Alignment Modes Double dots auxiliary
Exposure Manual /Auto
Photography SLR Camera
Image definition 24 Megapixel
Compensation ±25D
Fixation External /Internal (any position available)
DICOM 3.0 Support

Digital Fundus Camera in the world
Brand TOPCON(NW-400) DRS NEWVISION(RETICAM3100)
operation automatic(one key taking picutre)/manual automatic(one key taking picutre)/manual automatic(one key taking picutre)/manual
Acquisition modes fundus/anterior fundus/anterior/red-free filter fundus/anterior/red-free filter/FFA(optional)/FAF(optional)
Filed of view 45 degree 40-45degree 45-50degee
Mosic degee 80 degree 135degree
Minimum pipil size 3.3mm 3.5mm 3.3mm
Resolution above 18megapiexl sensor size:5 megapixel sensor resoultion: 48 pixel/degree above18 megapixel (24 megapixel optional )
Fixation 9 internal + 1 outside fixaiton 7 internal fixation countless fixaiton, any position is available during range + 1 outside fixation
Technology of focus Dual camrea technology
exposure ligh standard standard new technology, more soft, one patient same eye can take picuture consecutive with almost same performace

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto

Company Introduction

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto


Product Tags:

Ophthalmic Digital Fundus Camera

      

High Resolution Digital Fundus Camera

      

Fully Auto Digital Fundus Camera

      
Quality Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto for sale

Ophthalmic Digital Fundus Camera Optic Ultra High Resolution Fully Auto Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Chongqing Bio Newvision Medical Equipment Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)